| Sign In | Join Free | My portofva.com |
|
Brand Name : SINOMEMB
Model Number : SN U-HI-1-660
Certification : NSF
Place of Origin : China
MOQ : 5
Packaging Details : Standard export packaging
Core Components : uf membrane
Product name : hollow fiber ultrafiltration membrane, ultrafiltration system, PVC Hollow fiber UF membrane module
Pore size : customized., from 1μm to 0.05μm, 0.01micron, 1.0μm, 0.2μm
Usage : water treatment, Seawater Ionizer Desalination, Liquid Filter, remove bacterias, Purification
Module : Inside-out
Nominal Pore Size : 0.1 μm
Membrane Structure : Hollow Fiber
Membrane Material : Polyethersulfone (PES)
Surface Area : 10-100 m2
Water Flux : 50-80lmh
The core SINOMEMB ® series SN U-HI-1-660 hollow fiber UF membrane element membrane module is ideal for systems with a capacity of 50 m 3 /hr (220 gpm) and below. The 60-inch length of this module is more effective at treating a variety of feedwaters than longer modules. In addition, the diameter of the membrane module is 6 inches , and the size is small, which can realize a relatively compact design , which is very suitable for occasions with limited space , and helps customers to achieve a more economical membrane system design , and can be widely used in surface water and well water , seawater , industrial wastewater, secondary and tertiary treatment of sewage and other water treatment applications.
| Membrane element model | Effective membrane area ft 2 (m 2 ) | Effective volume G( L ) | weight empty /full of water ( kg ) |
| SN U-HI-1-660 | 355(33) | 4.2(16) | 25/41 |
| Inlet size | Water outlet size | Concentrated water outlet size | Membrane Polymer |
| DN50 | DN50 | DN32 | PES |
| Membrane inner diameter/outer diameter (mm) | Filtration precision (μ m ) | shell material | Sealant material |
| 1.0/1.6 | 0.01 | U-PVC | epoxy resin |
| Filtration flux ( 25℃ ) L/㎡·hr | 50-80 |
| Flow range m³/hr | 1.65-2.64 |
| Maximum influent turbidity (NTU) | ≤50 |
| Maximum resistance to residual chlorine (NaCLO) (ppm) | Continuous: 50; Momentary: 500 |
| Maximum anti-suspended solid capacity (ppm) | ≤50 |
| Maximum influent particle size ( μm ) | 100 |
| Working temperature (℃) | 1-40 |
| pH range | 1-13 |
| Maximum water production (L/m³·h) | 120 |
| Maximum inlet pressure (Mpa) | 0.625 |
| Maximum transmembrane pressure difference (Mpa) | 0.21 |
| Maximum backwash pressure (Mpa) | 0.25 |
| Maximum air flushing flow rate (Nm³/hr) | / |
| General backwash cycle (min) | 15-60 |
| General backwash time (sec) | 30-60 |
| General backwash flow rate (L/m³·h) | 100-360 |
| General chemical enhanced backwash cycle (day) | 1-15 |
| General chemical backwashing time (min) | 1-15 |
| General chemical cleaning cycle (day) | 30-180 |
| General chemical cleaning time (min) | 90-480 |
| General chemical cleaning chemicals | NaClO or H2O2 500ppm , NaOH (PH≤13), HCl (PH≥1 ) |
| How to run /operate | inside-out / full flow or cross flow filtration |
| Expected water production SDI | ≤2.5 |
| Expected product water turbidity NTU | ≤0.1 |
| Bacteria removal rate (log) | >6 |
| E. coli removal rate (log) | >6 |
| service life | ≥3 years under standard conditions |

| L | L1 | L2 | L3 | L4 | Diameter Φ |
| 1860mm | 1500mm | 1610mm | 1710mm | 125mm | 165mm |
| (73.2)in | (59.1)in | (63.4)in | (67.3)in | (4.9)in | (6.5)in |
SEM cross-section photograph.
Saveyor SVF membrane is made by unique technology called as "complex Thermally Induced Phase Separation" (c-TIPS)technology which endows to membrane with high crystallinity. As result, the membrane is good at chemical resistance,mechanical strength and longer life time.
The operation flux of most of UF or MF membrane products is much lower than their initial flux resulting from the loss of
membrane hydrophilicity by polymer reconfiguration. Saveyor PVDF UF membrane remains hydrophilic permanently and thus, offers steady flux.
Saveyor SVF Series membrane modules can be cleaned thoroughly by strong oxidant because of the chemical inertness of PVDF polymer.
An air diffuser is installed inside this series of Saveyor membrane modules so that air may be evenly distributed around
membrane capillaries. Water is "carried" upward by this air flow and "drain" downward through a central pipe and such
create a water recirculation current. This Air Lift Recirculation (ALR) current may greatly reduce membrane fouling.
The "roots" of the capillaries are the weakest portions in membrane modules, and may be broken during operation. These portions of membranes in Saveyor UF modules are protected by a soft layer of potting material.
Typically, Saveyor SVF membrane is designed to be run at pressure as low as 0.02MPa (3.0 psi) to produce enough water.
APPLICATIONS Saveyor SVF membrane modules can be used to purify well and surface water for drinking water, to filter sewage and waste water for water recycle, and to treat surface or sea water for RO and NF systems.
1) Advanced municipal water treatment and drinking water treatement
2) Advanced sewage treatment and reuse
3) Seawater desalination pretreatment
4) Conventional surface water/groundwater treatment
|
|
Water Treatment Hollow Fiber Ultrafiltration Membrane 0.01μM UF Membrane High Precision Images |